hamatic – Precise in all directions

To ensure that you are able to go in the right direction on the market, you need reliable products – just like our hamatic linear actuators. With linearity, precision and power, they bring technical components to the desired position. That´s why they are in high demand in the medical equipment field, for instance, hamatic actuators constantly and reliably move dental chairs, therapy couches, medical examining tables and many other medical devices, where both precise and smooth motion are vital.


Download brochure hamatic

Information for final consumers/private customers

Drive solutions for Medical applications

hamatic product examples

S 95

hamatic compact Frameless linear actuator S 95

SH 95

hamatic compact Frameless linear actuator SH 95

S 80

hamatic compact Frameless linear actuator S 80

SH 80

hamatic compact Frameless linear actuator SH 80

S 56

hamatic compact Frameless linear actuator S 56

SH 56

hamatic compact Frameless linear actuator SH 56

SL 95

hamatic cap Encapsulated linear actuator SL 95

SL 80

hamatic cap Encapsulated linear actuator SL 80

SL 56

hamatic cap Encapsulated linear actuator SL 56

HL 11

hamatic cap Linear actuator HL 11 with DC brush motor

HL 12

hamatic cap Linear actuator HL 12 with DC brush motor

Column THS-3

hamatic lift Column

hamatic compact
Frameless linear actuator S 95

hamatic compact Frameless linear actuator S 95

Technical specifications

  • Mains voltage: 1~ 100 / 115 / 230 V AC ± 10 %, 36 V DC via hatronic compact DC-FI frequency inverter
  • Max. forces: 8,000 to 10,000 N (medical equipment)
  • Speed: Up to 75 mm/s
  • Stroke: Up to 300 mm, above on request

hamatic compact
Frameless linear actuator SH 95

hamatic compact Frameless linear actuator SH 95

Technical specifications

  • Design: With support and travel tube
  • Mains voltage: 1~ 100 / 115 / 230 V AC ± 10 %, 36 V DC via hatronic compact DC-FI frequency inverter
  • Max. forces: 8,000 to 10,000 N (medical equipment)
  • Speed: 6 – 75 mm/s
  • Stroke: Up to 300 mm, above on request

hamatic compact
Frameless linear actuator S 80

hamatic compact Frameless linear actuator S 80

Technical specifications

  • Mains voltage: 1~ 100 / 115 / 230 V AC ± 10 %, 36 V DC via hatronic compact DC-FI frequency inverter
  • Max. forces: 8,000 to 10,000 N (medical equipment)
  • Speed: 3 – 24 mm/s
  • Stroke: Up to 300 mm, above on request

hamatic compact
Frameless linear actuator SH 80

hamatic compact Frameless linear actuator SH 80

Technical specifications

  • Design: With support and travel tube
  • Mains voltage: 1~ 100 / 115 / 230 V AC ± 10 %, 36 V DC via hatronic compact DC-FI frequency inverter
  • Max. forces: 8,000 to 10,000 N (medical equipment)
  • Speed: Up to 75 mm/s
  • Stroke: Up to 300 mm, above on request

hamatic compact
Frameless linear actuator S 56

hamatic compact Frameless linear actuator S 56

Technical specifications

  • Mains voltage: 1~ 100 / 115 / 230 V AC ± 10 %, 36 V DC via hatronic compact DC-FI frequency inverter
  • Max. forces: 4,000 to 6,000 N (medical equipment)
  • Speed: 3 – 24 mm/s
  • Stroke: Up to 300 mm, above on request

hamatic compact
Frameless linear actuator SH 56

hamatic compact Frameless linear actuator SH 56

Technical specifications

  • Design: With support and travel tube
  • Mains voltage: 1~ 100 / 115 / 230 V AC ± 10 %, 36 V DC via hatronic compact DC-FI frequency inverter
  • Max. forces: 4,000 to 6,000 N (medical equipment)
  • Speed: Up to 75 mm/s
  • Stroke: Up to 300 mm, above on request

hamatic cap
Encapsulated linear actuator SL 95

hamatic cap Encapsulated linear actuator SL 95

Technical specifications

  • Mains voltage: 1~ 100 / 115 / 230 V AC ± 10 %, 3~ 400 V,
    36 V DC via hatronic compact DC-FI frequency inverter
  • Max. forces: 12,000 N (industrial applications) or 10,000 N (medical technology)
  • Speed: 3 – 50 mm/s variable
  • Stroke: Up to 500 mm, above on request

hamatic cap
Encapsulated linear actuator SL 80

hamatic cap Encapsulated linear actuator SL 80

Technical specifications

  • Mains voltage: 1~ 100 / 115 / 230 V AC ± 10 %, 36 V DC via hatronic compact DC-FI frequency inverter
  • Max. forces: 8,000 N
  • Speed: 3 – 18 mm/s
  • Stroke: Up to 300 mm, above on request

hamatic cap
Encapsulated linear actuator SL 56

hamatic cap Encapsulated linear actuator SL 56

Technical specifications

  • Mains voltage: 1~ 100 / 115 / 230 V AC ± 10 %, 36 V DC via hatronic compact DC-FI frequency inverter
  • Max. forces: 6,000 N
  • Speed: 3 – 18 mm/s
  • Stroke: Up to 300 mm, above on request

hamatic cap
Linear actuator HL 11 with DC brush motor

hamatic cap Linear actuator HL 11 with DC brush motor

Technical specifications

  • Power supply: via HC 1 control box
  • Max. forces: 6,000 N
  • Speed: 2.5 – 4 mm/s
  • Stroke: 100, 200 oder 300 mm

hamatic cap
Linear actuator HL 12 with DC brush motor

hamatic cap Linear actuator HL 12 with DC brush motor

Technical specifications

  • Power supply: via HC 1 control box
  • Max. forces: 8,000 N
  • Speed: 4 – 6 mm/s
  • Stroke: 100, 200 oder 300 mm

hamatic lift
Column

hamatic lift Column

Technical specifications

  • Mains voltage: 1~ 100 / 115 / 230 V AC ± 10 % 50/60 Hz (medical application)
    3~ 400/480 V AC ± 10 % 50/60 Hz (industrial applicaton)
    36 V DC via hatronic compact frequency inverter DC-FI
  • Max. forces: 5,000 N (medical application), 7,000 N (industrial application)
  • Speed: Up to 32 mm/s
  • Stroke: Up to 500 mm

Drive solutions for industrial applications

hamatic product examples

S 95

hamatic compact Frameless linear actuator S 95

SH 95

hamatic compact Frameless linear actuator SH 95

S 80

hamatic compact Frameless linear actuator S 80

SH 80

hamatic compact Frameless linear actuator SH 80

S 56

hamatic compact Frameless linear actuator S 56

SH 56

hamatic compact Frameless linear actuator SH 56

SHI 120

hamatic pro Linear actuator SHI 120 with housing

SHI 95

hamatic pro Linear actuator SHI 95 with housing

SL 95

hamatic cap Encapsulated linear actuator SL 95

SL 80

hamatic cap Encapsulated linear actuator SL 80

SL 56

hamatic cap Encapsulated linear actuator SL 56

HL 11

hamatic cap Linear actuator HL 11 with DC brush motor

HL 12

hamatic cap Linear actuator HL 12 with DC brush motor

Column THS-3

hamatic lift Column

hamatic compact
Frameless linear actuator S 95

hamatic compact Frameless linear actuator S 95

Technical specifications

  • Mains voltage: 1~ 100 / 115 / 230 V AC ± 10 %, 36 V DC via hatronic compact DC-FI frequency inverter
  • Max. forces: 8,000 to 10,000 N (medical equipment)
  • Speed: Up to 75 mm/s
  • Stroke: Up to 300 mm, above on request

hamatic compact
Frameless linear actuator SH 95

hamatic compact Frameless linear actuator SH 95

Technical specifications

  • Design: With support and travel tube
  • Mains voltage: 1~ 100 / 115 / 230 V AC ± 10 %, 36 V DC via hatronic compact DC-FI frequency inverter
  • Max. forces: 8,000 to 10,000 N (medical equipment)
  • Speed: 6 – 75 mm/s
  • Stroke: Up to 300 mm, above on request

hamatic compact
Frameless linear actuator S 80

hamatic compact Frameless linear actuator S 80

Technical specifications

  • Mains voltage: 1~ 100 / 115 / 230 V AC ± 10 %, 36 V DC via hatronic compact DC-FI frequency inverter
  • Max. forces: 8,000 to 10,000 N (medical equipment)
  • Speed: 3 – 24 mm/s
  • Stroke: Up to 300 mm, above on request

hamatic compact
Frameless linear actuator SH 80

hamatic compact Frameless linear actuator SH 80

Technical specifications

  • Design: With support and travel tube
  • Mains voltage: 1~ 100 / 115 / 230 V AC ± 10 %, 36 V DC via hatronic compact DC-FI frequency inverter
  • Max. forces: 8,000 to 10,000 N (medical equipment)
  • Speed: Up to 75 mm/s
  • Stroke: Up to 300 mm, above on request

hamatic compact
Frameless linear actuator S 56

hamatic compact Frameless linear actuator S 56

Technical specifications

  • Mains voltage: 1~ 100 / 115 / 230 V AC ± 10 %, 36 V DC via hatronic compact DC-FI frequency inverter
  • Max. forces: 4,000 to 6,000 N (medical equipment)
  • Speed: 3 – 24 mm/s
  • Stroke: Up to 300 mm, above on request

hamatic compact
Frameless linear actuator SH 56

hamatic compact Frameless linear actuator SH 56

Technical specifications

  • Design: With support and travel tube
  • Mains voltage: 1~ 100 / 115 / 230 V AC ± 10 %, 36 V DC via hatronic compact DC-FI frequency inverter
  • Max. forces: 4,000 to 6,000 N (medical equipment)
  • Speed: Up to 75 mm/s
  • Stroke: Up to 300 mm, above on request

hamatic pro
Linear actuator SHI 120 with housing

hamatic pro Linear actuator SHI 120 with housing

Technical specifications

  • Mains voltage: 3~ 380 – 480 V ± 10 % AC
  • Max. forces: 25,000 N
  • Speed: 28 mm/s (50 Hz)
  • Stroke: 250, 500 mm

hamatic pro
Linear actuator SHI 95 with housing

hamatic pro Linear actuator SHI 95 with housing

Technical specifications

  • Mains voltage:: 1~ 100 / 115 / 230 V ± 10% AC,
    3~ 380 – 480 V
  • Max. forces: 12,000 N
  • Speed: 6 – 75 mm/s
  • Stroke: On request

hamatic cap
Encapsulated linear actuator SL 95

hamatic cap Encapsulated linear actuator SL 95

Technical specifications

  • Mains voltage: 1~ 100 / 115 / 230 V AC ± 10 %, 3~ 400 V,
    36 V DC via hatronic compact DC-FI frequency inverter
  • Max. forces: 12,000 N (industrial applications) or 10,000 N (medical technology)
  • Speed: 3 – 50 mm/s variable
  • Stroke: Up to 500 mm, above on request

hamatic cap
Encapsulated linear actuator SL 80

hamatic cap Encapsulated linear actuator SL 80

Technical specifications

  • Mains voltage: 1~ 100 / 115 / 230 V AC ± 10 %, 36 V DC via hatronic compact DC-FI frequency inverter
  • Max. forces: 8,000 N
  • Speed: 3 – 18 mm/s
  • Stroke: Up to 300 mm, above on request

hamatic cap
Encapsulated linear actuator SL 56

hamatic cap Encapsulated linear actuator SL 56

Technical specifications

  • Mains voltage: 1~ 100 / 115 / 230 V AC ± 10 %, 36 V DC via hatronic compact DC-FI frequency inverter
  • Max. forces: 6,000 N
  • Speed: 3 – 18 mm/s
  • Stroke: Up to 300 mm, above on request

hamatic cap
Linear actuator HL 11 with DC brush motor

hamatic cap Linear actuator HL 11 with DC brush motor

Technical specifications

  • Power supply: via HC 1 control box
  • Max. forces: 6,000 N
  • Speed: 2.5 – 4 mm/s
  • Stroke: 100, 200 oder 300 mm

hamatic cap
Linear actuator HL 12 with DC brush motor

hamatic cap Linear actuator HL 12 with DC brush motor

Technical specifications

  • Power supply: via HC 1 control box
  • Max. forces: 8,000 N
  • Speed: 4 – 6 mm/s
  • Stroke: 100, 200 oder 300 mm

hamatic lift
Column

hamatic lift Column

Technical specifications

  • Mains voltage: 1~ 100 / 115 / 230 V AC ± 10 % 50/60 Hz (medical application)
    3~ 400/480 V AC ± 10 % 50/60 Hz (industrial applicaton)
    36 V DC via hatronic compact frequency inverter DC-FI
  • Max. forces: 5,000 N (medical application), 7,000 N (industrial application)
  • Speed: Up to 32 mm/s
  • Stroke: Up to 500 mm